Metal stud wall & partition calculator
Use the wall length, height and stud centres to estimate framing and boards to order, including stock lengths and splice allowances.
For spliced uprights, effective assembled height is total stud material minus 600 mm for each splice. Base track remains the full partition length. Head track adds 1.30 m per single door and 2.10 m per double door. Board quantities can be calculated for one or two layers each side. The stud recommendation compares 3.6 m, 4.2 m, 4.8 m, 5.0 m and 6.0 m stock lengths and minimises total extra stud material, so splice overlap is counted as inefficiency as well as cutting offcut.